Lidar/Radar Automotive Thermal Forcing System
The Lidar/Radar Thermal Forcing system is based on Samson Cooling Engine and customed per specific dimensions of any Lidar/Radar. It was designed to be used as laboratory equipment to validate Lidar / Radar boxes in temperature ranges of -40ºc up to +125ºc at cooling / heating envelope between 150W@-40ºc 650W@0ºc with option to be mounted on a gimbal with rotation option as well The Samson system has the capability to be mounted on a vehicle with hose length up to 5 Meres. Samson Air cooling requires standard 208-230V 50Hz or 110-130V 60Hz outlet only.
Features
Temperature range | -40ºc to 125ºc |
Cooling power | 150W@-40/0º, 280W@-24/0º, 650w@/0ºc |
Temperature change rate | ~(hot/cold): 3ºc per second |
Condensation prevention | Air Purge & Heaters |
Umbilical hose length | 2.3-5 meters (between control box & thermal head) |
Remote communication | I^2C / Modbus TCP/UDP Protocols |
Refrigeration | R452a – complies with CA state GWP regulation (2020) |